Fire Alarm Systems


The equipment is LPCB listed.

 

Download the catalogue of System 6300 of Protec Fire Detection - HERE

 

We offer the sophisticated analogue addressable fire alarm system, with capacity to detect the exact location of the detector, which has received, analyzed and notified the event of fire. They are equipped with a standard interface for transferring the information about the occurring events in a total building control computer system. The system components are of high quality and have excellent parameters and competitive prices.

With the system programming, each address will be assigned the necessary functions, regardless its physical location. The sensors and other devices are installed along the loops. In the event of fire, the building automation system would be controlled by the fire alarm system, independently of the other equipment. If functional or architectural changes should occur, the system can be easily programmed anew, so as to reflect the changes. The automatic self-test built into the system verifies all aspects of each sensors operation and communication, including its sensitivity to smoke and calibration level. The system is unique in its ability to identify system faults, and take remedial action. The system can incorporate a single fire control panel or a number of panels, working in a peer-to-peer network.

 

The ‘sensitivity range’ is the key feature that makes the Cirrus Pro Series Fire Detector the worlds most versatile fire detection device. For over 20 years Cloud Chamber detectors have been known as the most sensitive fire detection device, able to detect at the true incipient stage of a developing fire.
The New Cirrus Pro Series Detectors have a vast sensitivity range capable of being even more sensitive than previous versions. In addition the detector may now be configured to be installed in heavily contaminated environments, such as polluted production and warehousing facilities.


ALMOST UNLIMITED APPLICATIONS
High Sensitivity Applications include:  Computer Rooms, Clean Rooms, Control Rooms, Data Centres, Valve Halls, Archive Storage, Anechoic Chambers, EDP areas.
General Sensitivity Applications include: Historic Buildings, Museums, Hospitals, Cathedrals, Theatres, Art Galleries, Clean Warehouses, Atria, Indoor Stadiums.
Harsh Environment Applications include: Cold Storage Facilities, Specialist Production Facilities, Food Industry Facilities, Paper Production Facilities, Transportation Terminals, Flight Simulators, Aircraft Hangers, Prisons, Inaccessible Voids, Dirty Warehouses.


 